USER_INFO_11  J97HNZ 

The USER_INFO_11 structure contains user information for network accounts.

typedef struct _USER_INFO_11 { 
    LPWSTR    usri11_name;
    LPWSTR    usri11_comment;
    LPWSTR    usri11_usr_comment;
    LPWSTR    usri11_full_name;
    DWORD     usri11_priv;
    DWORD     usri11_auth_flags;
    DWORD     usri11_password_age;
    LPWSTR    usri11_home_dir;
    LPWSTR    usri11_parms;
    DWORD     usri11_last_logon;
    DWORD     usri11_last_logoff;
    DWORD     usri11_bad_pw_count;
    DWORD     usri11_num_logons;
    LPWSTR    usri11_logon_server;
    DWORD     usri11_country_code;
    LPWSTR    usri11_workstations;
    DWORD     usri11_max_storage;
    DWORD     usri11_units_per_week;
    PBYTE     usri11_logon_hours;
    DWORD     usri11_code_page;
}USER_INFO_11, *PUSER_INFO_11, *LPUSER_INFO_11;

 

Members

usri11_name

Specifies the name of the user account. For NetUserSetInfo, this member is ignored. The number of characters in the name cannot exceed the value of UNLEN.

usri11_comment

Points to a Unicode string that contains a user comment. This string can be a null string, or it can have any number of characters before the terminating null character.

usri11_usr_comment

Points to a Unicode string that contains a user comment. This string can be a null string, or it can have any number of characters before the terminating null character.

usri11_full_name

Points to a Unicode string that contains the full name of the user. This string can be a null string, or it can have any number of characters before the terminating null character.

usri11_priv

One of three values specifying the level of privilege assigned the usri11_name member. For NetUserAdd, this member must be USER_PRIV_USER. For NetUserSetInfo, this member must be the value returned from NetUserGetInfo or NetUserEnum. This member can be one of the following values:

Value

Meaning

USER_PRIV_GUEST

Guest

USER_PRIV_USER

User

USER_PRIV_ADMIN

Administrator

 

usri11_auth_flags

Specifies an unsigned long integer that contains values that specify the user's operator privileges.

For Windows NT servers, the following restrictions apply; for NetUserAddI5025I, this member must be 0. For NetUserSetInfo.UX_.U, this member must be the value returned from NetUserGetInfoFPY53H or NetUserEnumLD4PB..

For NetUserGetInfo or NetUserEnum, the appropriate value is returned based on the local group membership. If the user is a member of Print Operations, AF_OP_PRINT is set. If the user is a member of Server Operations, AF_OP_SERVER is set. If the user is a member of the Account Operations, AF_OP_ACCOUNTS is set. AF_OP_COMM is never set.

The NetUserAddI5025I and NetUserSetInfo.UX_.U functions ignore this member.

This member can be one of the following values:

Value

Meaning

AF_OP_PRINT

The print operator privilege is enabled.

AF_OP_COMM

The communications operator privilege is enabled.

AF_OP_SERVER

The server operator privilege is enabled.

AF_OP_ACCOUNTS

The accounts operator privilege is enabled.

 

usri11_password_age

Specifies the number of seconds elapsed since the usri11_password member was last changed. The NetUserAddI5025I and NetUserSetInfo.UX_.U functions ignore this member.

usri11_home_dir

Points to a Unicode string containing the path of the home directory for the user specified in the user_name member. The string can be null.

usri11_parms

Points to a Unicode string that is set aside for use by applications. This string can be a null string, or it can have any number of characters before the terminating null character. Microsoft products use this member to store user configuration information. Do not modify this information. usri11_last_logon

Specifies when the last logon occurred. This value is stored as the number of seconds elapsed since 00:00:00, January 1, 1970. This member is ignored in NetUserAddI5025I and NetUserSetInfo.UX_.U calls. This member is maintained separately on each Backup Domain Controller (BDC) in the domain. To get an accurate value, each BDC in the domain must be queried, and the largest value is used.

usri11_last_logoff

Specifies when the last logoff occurred. This value is stored as the number of seconds elapsed since 00:00:00, January 1, 1970. A value of zero means that the last logoff time is unknown. This element is ignored in NetUserAdd and NetUserSetInfo calls. This member is maintained separately on each Backup Domain Controller (BDC) in the domain. To get an accurate value, each BDC in the domain must be queried, and the largest value is used.

usri11_bad_pw_count

Specifies the number of times the user tried to log on to this account using an incorrect password. A value of 0xFFFFFFFF indicates that the value is unknown. This member is ignored in NetUserAddI5025I and NetUserSetInfo.UX_.U calls. This member is maintained separately on each Backup Domain Controller (BDC) in the domain. To get an accurate value, each BDC in the domain must be queried, and the largest value is used.

usri11_num_logons

Counts the number of successful times the user tried to log on to this account. A value of 0xFFFFFFFF indicates that the value is unknown. This element is ignored in NetUserAdd and NetUserSetInfo calls. This member is maintained separately on each Backup Domain Controller (BDC) in the domain. To get an accurate value, each BDC in the domain must be queried, and the member uses the sum of the values.

usri11_logon_server

Points to a Unicode string that contains the name of the server to which logon requests are sent. Servernames should be preceded by two backslashes (\\). When a servername is indicated by an asterisk (\\*), the logon request can be handled by any logon server. A null string indicates that requests are sent to the domain controller. For Windows NT Servers, NetUserGetInfoFPY53H and NetUserEnumLD4PB. return \\*. The NetUserAdd and NetUserSetInfo functions ignore this member.

usri11_country_code

Specifies the country code for the user's language of choice.

usri11_workstations

Points to a Unicode string that contains the names of workstations from which the user can log on. As many as eight workstations can be specified; the names must be separated by commas (,). A null string indicates that there is no restriction. To disable logons from all workstations to this account, set the UF_ACCOUNTDISABLE value in the usri*_flags member.

usri11_max_storage

Specifies the maximum amount of disk space the user can use. Use the value specified in USER_MAXSTORAGE_UNLIMITED to use all available disk space.

usri11_units_per_week

Specifies the number of equal-length time units into which the week is divided. The usri11_units_per_week member uses these time units to compute the length of the bit string in the usri2_logon_hours member. This value must be UNITS_PER_WEEK for LAN Manager 2.0. This element is ignored in the NetUserAddI5025I and NetUserSetInfo.UX_.U functions. For Windows NT services, the units must be one of the following: SAM_DAYS_PER_WEEK, SAM_HOURS_PER_WEEK, or SAM_MINUTES_PER_WEEK.

usri11_logon_hours

Points to a 21-byte (168 bits) bit string that specifies the times during which the user can log on. Each bit represents a unique hour in the week. The first bit (bit 0, word 0) is Sunday, 0:00 to 0:59; the second bit (bit 1, word 0) is Sunday, 1:00 to 1:59; and so on. A null pointer in this member for NetUserAdd calls means that there is no time restriction. A null pointer in this element for NetUserSetInfo calls means that no change is to be made.

usri11_code_page

Specifies the code page for the user's language of choice.

 

See Also

NetUserAdd, NetUserDel, NetUserEnum, NetUserGetInfo, NetUserSetInfo