MCI_RECORD
The MCI_RECORD
command starts recording from the current position or from one specified
location to another specified location. VCR and waveform-audio devices
recognize this command. Although digital-video devices and MIDI sequencers also
recognize this command, the MCIAVI and MCISEQ drivers do not implement it.
MCIERROR mciSendCommand(MCIDEVICEID wDeviceID,
MCI_RECORD,
DWORD
dwFlags, (DWORD) (LPMCI_RECORD_PARMS) lpRecord);
Parameters
wDeviceID
Device
identifier of the MCI device that is to receive the command message.
dwFlags
MCI_NOTIFY,
MCI_WAIT, or, for digital-video and VCR devices, MCI_TEST. For information
about these flags, see The Wait, Notify, and Test Flags
lpRecord
Address of an
MCI_RECORD_PARMS
Return Values
Returns zero
if successful or an error otherwise.
Remarks
This command
is supported by devices that return TRUE when you call the MCI_GETDEVCAPS
The following
additional flags apply to all devices supporting MCI_RECORD:
MCI_FROM
A starting
location is included in the dwFrom member of the structure identified by
lpRecord. The units assigned to the position values are specified with
the MCI_SET_TIME_FORMAT flag of the MCI_SET
MCI_RECORD_INSERT
Newly
recorded information should be inserted or pasted into the existing data. Some
devices might not support this. If supported, this is the default.
MCI_RECORD_OVERWRITE
Data should
overwrite existing data. The MCIWAVE.DRV device returns
MCIERR_UNSUPPORTED_FUNCTION in response to this flag.
MCI_TO
An ending
location is included in the dwTo member of the structure identified by lpRecord.
The units assigned to the position values are specified with the MCI_SET_TIME_FORMAT
flag of the MCI_SET
The following
additional flags are used with the digitalvideo device type:
MCI_DGV_RECORD_AUDIO_STREAM
An
audio-stream number is included in the dwAudioStream member of the
structure identified by lpRecord. If you omit this flag, audio data is
recorded into the first physical stream.
MCI_DGV_RECORD_HOLD
When
recording stops, the screen will hold the last image and will not resume showing
the video until an MCI_MONITOR
MCI_DGV_RECORD_VIDEO_STREAM
A
video-stream number is included in the dwVideoStream member of the
structure identified by lpRecord. If you omit this flag, video data is
recorded into the first physical stream.
MCI_DGV_RECT
A rectangle
is specified in the rc member of the structure identified by lpRecord.
The rectangle specifies the region of the external input used as the source for
the pixels compressed and saved. This rectangle defaults to the rectangle
specified (or defaulted) by the MCI_DGV_PUT_VIDEO flag for the MCI_PUT
For
digital-video devices, lpRecord points to an MCI_DGV_RECORD_PARMS
The following
additional flags are used with the vcr device type:
MCI_VCR_RECORD_AT
The dwAt member
of the structure identified by lpRecord contains a time when the entire
command begins, or if the device is cued, when the device reaches the from
position given by the cue command.
MCI_VCR_RECORD_INITIALIZE
Seek the
device to the start of the media, begin recording blank video and audio, and
record timecode, if possible.
For VCR
devices, lpRecord points to an MCI_VCR_RECORD_PARMS
See Also